Keyboard Part Number List

56 keyboards found/on record...

Unicomp Customizer for General Electric Marquette

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
UNZ4416
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2000
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Marquette rectangle & Unicomp logo across lock-light LEDs overlay
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad's number keys lack navigation sublegends

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-017
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Swedish ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-006
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Spanish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-007
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Italian ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-008
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
French ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-009
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
German ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-010
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Spanish ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-011
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Italian ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-012
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
French ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-013
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
German ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-014
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Spanish ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-015
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Italian ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-016
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Swedish ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-018
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Swedish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-004
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
French ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-019
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI /w Chinese secondary characters
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-020
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI /w Chinese secondary characters
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-021
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI /w Chinese secondary characters
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-022
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Danish ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-023
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Danish ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-024
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Danish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-025
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Dutch ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-026
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Dutch ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-027
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Dutch ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-028
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Norwegian ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-029
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Norwegian ISO
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-005
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
German ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-003
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
ASK: SNKB-M2013-EGE-101
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

Unicomp Customizer for General Electric Marquette

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
UNZ3416
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2002
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Marquette rectangle & Unicomp logo across lock-light LEDs overlay
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-009
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
German ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003810-009
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

Unicomp Customizer for General Electric Marquette

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
UNZ2416
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2003
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Marquette rectangle & Unicomp logo across lock-light LEDs overlay
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps

Unicomp Customizer for General Electric Marquette

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2003809-001
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2006
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Marquette rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps

Unicomp Customizer for General Electric Marquette

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2003809-003
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2006
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Marquette rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-001
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2011
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-001
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]
Web: https://web.archive.org/web/20221215225404/https://www.ebay.com/itm/285056714119?orig_cvip=true

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-002
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-002
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-003
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-003, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-004
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
French ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-004, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-005
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
German ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-005, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-006
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Spanish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-006, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-007
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Italian ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-007, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-008
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
French ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003810-008
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-010
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Spanish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003810-010
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-002
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-011
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Italian ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003810-011
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-012
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
French ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-012
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-013
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
German ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-013
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-014
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Spanish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-014
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-015
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Italian ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-015
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-016
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Swedish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003810-016
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-017
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Swedish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-017
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-018
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Swedish ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-018, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-019
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI /w Chinese secondary characters
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003810-019
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-020
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI /w Chinese secondary characters
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-020
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Version 6.5.6 R2 (#2021423-503H) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2045802-021
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Pearl White
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
White straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI /w Chinese secondary characters
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
Replaced earlier GE P/N 2003809-021, F-keys entirely replaced with specialised legends, some of the alphanumeric section has secondary legends, and the numeric keypad has a bright yellow "VEN" key in place of a 0/Ins key

General Electric Healthcare Mac-Lab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-001
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
101
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
US ANSI
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]

General Electric Healthcare Mac-Lab & CardioLab Keyboard

Part NumberPart Number
The number used to describe this keyboard's specific release; usually specific for a target region, language or SKU, etc.
2054858-030
TypeType
A designation from my own type naming scheme used to categorise this keyboard with or from others by their common features and market intent but may/may not be derived from official names.
Model M Enhanced PC Keyboard (Healthcare Systems)
OEMOEM
Possible companies responsible for making this keyboard for the company marketing it.
Unicomp
KeyswitchesKeyswitches
The name of the known switching mechanism that lies under this keyboard's keys.
IBM membrane buckling springs
Earliest AppearanceEarliest Appearance
The year (and possibly the quarter) that this keyboard part number was introduced, first observed, first recorded or the first example found.
2013
Original KeycapsOriginal Keycaps
The keyboard's original keycaps' material and text/symbol printing technique.
PBT with dye-sublimated legends
Cover ColourCover Colour
The original colour of this keyboard's cover set (outer casing). For keyboards whose cover set materials are known to yellow, this will refer to the original colour before such transformation occurs.
Raven Black/Stealth Black
BrandingBranding
The possible branding and logo styles found on this keyboard part number. This could be multiple styles at once or possible styles found over time.
GE Healthcare rectangle
FeetFeet
The style of this keyboard's flip-out or extendable feet. If applicable, this may also state how many levels of height adjustment are available and whether the feet could be rubberised.
Single-setting flip-out feet
ProtocolProtocol
The protocol(s) this keyboard can use to speak to the host computer (eg, scancode sets).
IBM Mode 2 (scancode set 2)
ConnectionConnection
The keyboard-to-host connection. This is could be a description of a cable (its colour, whether its coiled, whether its detachable, and what connector is at its end) or the name of a wireless technology.
Black straightened-style fixed 6-pin mini-DIN PS/2 cable
Key CountKey Count
The number of keys that this keyboard originally had.
102
Form FactorForm Factor
The standardised or universally acknowledged name for this keyboard's layout form factor.
Full-size
Layout/LanguageLayout/Language
Image of Layout/LanguageThe original regional/language layout this keyboard was configured as. Both the language and the standardised key layout may be listed, and in the case of both being known or defined, it will be styled as language then standard.
Norwegian ISO
Additional NotesAdditional Notes
Extra notes about this keyboard that may be of interest or are important to know.
F-keys and numeric keypad legends entirely replaced with specialised legends, most of the alphanumeric section has secondary and tertiary legends, Alt keys replaced with "Action" keys, and the numeric keypad largely has bright yellow keycaps
Source(s)Source(s)
Documents ("Doc"), websites and/or webpages ("Web") that were used as a source of information for this keyboard part number. Examples of this keyboard part number I own ("ASK") will also be included as sources.
Doc: GE Healthcare Mac-Lab/CardioLab/Centricity Cardiology INW Service Manual Software Version 6.9.6 R2 (#2088535-010F) [source: EWH BMET Library]